AS Alternative Solution

2 QUEEN ST E, Toronto

Permit details

Application
24 162485 ALT rev 00
Address
2 QUEEN ST E, Toronto (M5C)
full property record — every permit and signal at this address
Work
Alternative Solution
Structure
Status
Deficiency Notice Issued
Applied
2024-06-10
Issued
Declared value
Builder
Owner-filed

Scope of work (as filed)

Elevator shafts are permitted to penetrate the floor fire separations when a 1 hour fire separation are provided [Sentence 3.13.2.1.(8)]. The elevator shaft enclosures in the station pass through floor assemblies that are required fire separations. The portion of elevator shafts that interface with public circulation spaces is constructed of laminated tempered glass panes that are supported by steel construction. The configuration is not recognized as a system that provides a fire separation with 1 hour fire-resistance rating.The alternative solution is required to demonstrate a level of performance with respect to the attributed objectives and functional statements to the acceptable solution. An alternative solution is proposed to 2012 OBC Sentence 3.13.2.1.(8).The objective is to support the use of a laminated and tempered glass assembly for elevator shafts. The proposed analysis is to examine the thermal exposure from credible fire scenarios to determine the performance of the elevator shaft glazing system and demonstrate that it mitigates the spread of fire and smoke via the shaft.

GROUND intelligence

Is this project worth chasing?

Likely scopes · competitive activity · lifecycle stage · opportunity score · fit for your trade.

Analyze this project →
GROUND services · Toronto & GTA

Planning something similar?

If you're an owner or tenant planning comparable work, we'll tell you what it should cost — read from records like this one — and introduce insured contractors with a track record on it.

Free, no obligation. If you ask for introductions, your request goes only to the contractors we match — never onto a list.